subdermal needle electrodes Search Results


90
Xomed Surgical Products 22-mm twisted pair needle electrodes
22 Mm Twisted Pair Needle Electrodes, supplied by Xomed Surgical Products, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/subdermal+needle+electrodes/subdermal+needle+electrodes/pmc07669316-75-5-8
Average 90 stars, based on 1 article reviews
22-mm twisted pair needle electrodes - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
Nicolet Biomedical concentric or a bipolar needle electrode nicolet biomedical
Concentric Or A Bipolar Needle Electrode Nicolet Biomedical, supplied by Nicolet Biomedical, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/subdermal+needle+electrodes/subdermal+needle+electrodes/pm16775202-68-11-14
Average 90 stars, based on 1 article reviews
concentric or a bipolar needle electrode nicolet biomedical - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
Technomed GmbH subcutaneous scalp needle electrodes
Subcutaneous Scalp Needle Electrodes, supplied by Technomed GmbH, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/subdermal+needle+electrodes/subdermal+needle+electrodes/bio_rxiv__254821-129-14-17
Average 90 stars, based on 1 article reviews
subcutaneous scalp needle electrodes - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
Technomed GmbH disposable concentric 30-gauge needle electrode technomed europe
Disposable Concentric 30 Gauge Needle Electrode Technomed Europe, supplied by Technomed GmbH, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/subdermal+needle+electrodes/subdermal+needle+electrodes+technomed+europe/pmc07260590__mmc1-121-14-19
Average 90 stars, based on 1 article reviews
disposable concentric 30-gauge needle electrode technomed europe - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
Ambu AS three 24- gauge stainless steel subdermal needle electrodes (neuroline subdermal
Three 24 Gauge Stainless Steel Subdermal Needle Electrodes (Neuroline Subdermal, supplied by Ambu AS, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/subdermal+needle+electrodes/single+needle+electrodes+ambu+neuroline+subdermal+12/pm29099622-64-13-21
Average 90 stars, based on 1 article reviews
three 24- gauge stainless steel subdermal needle electrodes (neuroline subdermal - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
AstroNova platinum subdermal needle electrode f-e2
Platinum Subdermal Needle Electrode F E2, supplied by AstroNova, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/subdermal+needle+electrodes/platinum+subdermal+needle+electrodes+model+f+e2/pm21997238-41-1-10
Average 90 stars, based on 1 article reviews
platinum subdermal needle electrode f-e2 - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
AstroNova platinum needle electrodes
Platinum Needle Electrodes, supplied by AstroNova, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/subdermal+needle+electrodes/platinum+subdermal+needle+electrodes/pmc07819847-34-1-4
Average 90 stars, based on 1 article reviews
platinum needle electrodes - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
Comepa Industries SAS subdermal needle electrode
Subdermal Needle Electrode, supplied by Comepa Industries SAS, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/subdermal+needle+electrodes/subdermal+needle+electrode/pmc02077517-70-9-17
Average 90 stars, based on 1 article reviews
subdermal needle electrode - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
Nicolet Biomedical 29 gauge subdermal needle electrodes
29 Gauge Subdermal Needle Electrodes, supplied by Nicolet Biomedical, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/subdermal+needle+electrodes/29+gauge+subdermal+needle+electrodes/pmc02913583-70-9-20
Average 90 stars, based on 1 article reviews
29 gauge subdermal needle electrodes - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
Nicolet Biomedical subdermal needle electrodes ear tips
Subdermal Needle Electrodes Ear Tips, supplied by Nicolet Biomedical, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/subdermal+needle+electrodes/subdermal+needle+electrodes+ear+tips/pmc05705878-42-1-8
Average 90 stars, based on 1 article reviews
subdermal needle electrodes ear tips - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
TransOral Pharmaceuticals subdermal needle electrode (25 and 38-mm long, insulated to within of tip)
Current published papers on AL EMG recording technique during neuromonitored thyroid and parathyroid surgery.
Subdermal Needle Electrode (25 And 38 Mm Long, Insulated To Within Of Tip), supplied by TransOral Pharmaceuticals, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/subdermal+needle+electrodes/subdermal+needle+electrode++25+and+38+mm+long++insulated+to+within+of+tip+/pmc08586463-11-15-45
Average 90 stars, based on 1 article reviews
subdermal needle electrode (25 and 38-mm long, insulated to within of tip) - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
Technomed GmbH disposable subdermal needle electrodes 27g
Current published papers on AL EMG recording technique during neuromonitored thyroid and parathyroid surgery.
Disposable Subdermal Needle Electrodes 27g, supplied by Technomed GmbH, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/subdermal+needle+electrodes/disposable+subdermal+needle+electrodes+27g/pm31369331-48-14-7
Average 90 stars, based on 1 article reviews
disposable subdermal needle electrodes 27g - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

Image Search Results


Current published papers on AL EMG recording technique during neuromonitored thyroid and parathyroid surgery.

Journal: Frontiers in Endocrinology

Article Title: New Developments in Anterior Laryngeal Recording Technique During Neuromonitored Thyroid and Parathyroid Surgery

doi: 10.3389/fendo.2021.763170

Figure Lengend Snippet: Current published papers on AL EMG recording technique during neuromonitored thyroid and parathyroid surgery.

Article Snippet: Percutaneous , Experimental Clinical , Huang et al., 2020 ( ) , Two disposable paired subdermal needle electrodes (25 and 38-mm long, insulated to within 5 mm of tip) percutaneously inserted to TC , Porcine model. (4 pigs, 8 RLNs at risk), 1 case of Transoral robotic thyroidectomy , A proof of concept for percutaneous technique in remote endoscopic or robotic thyroidectomy without neck incision wound..

Techniques: Adhesive, Introduce

Anatomic relationship between the thyroid cartilage (TC) - vocal folds and intraoperative neural monitoring (IONM) recording electrode placement in different electromyography (EMG) recording techniques used in thyroid and parathyroid surgery. The vocal fold (VF, vocalis and thyroarytenoid muscle) originates from the inner surface of the TC and inserts to the arytenoid cartilage (A). Conventional endotracheal tube (ET) surface electrodes are designed to be placed in contact with vocal folds during intubation for general anesthesia. However, potential displacement of the ET electrode during surgery may affect signal quality and stability. Recent studies have confirmed that anterior laryngeal (AL) transcartilage, percutaneous, and transcutaneous surface recording electrodes placed on the TC outer surface also enable access to the EMG response of the vocal folds and can circumvent factors that negatively affect ET electrode performance.

Journal: Frontiers in Endocrinology

Article Title: New Developments in Anterior Laryngeal Recording Technique During Neuromonitored Thyroid and Parathyroid Surgery

doi: 10.3389/fendo.2021.763170

Figure Lengend Snippet: Anatomic relationship between the thyroid cartilage (TC) - vocal folds and intraoperative neural monitoring (IONM) recording electrode placement in different electromyography (EMG) recording techniques used in thyroid and parathyroid surgery. The vocal fold (VF, vocalis and thyroarytenoid muscle) originates from the inner surface of the TC and inserts to the arytenoid cartilage (A). Conventional endotracheal tube (ET) surface electrodes are designed to be placed in contact with vocal folds during intubation for general anesthesia. However, potential displacement of the ET electrode during surgery may affect signal quality and stability. Recent studies have confirmed that anterior laryngeal (AL) transcartilage, percutaneous, and transcutaneous surface recording electrodes placed on the TC outer surface also enable access to the EMG response of the vocal folds and can circumvent factors that negatively affect ET electrode performance.

Article Snippet: Percutaneous , Experimental Clinical , Huang et al., 2020 ( ) , Two disposable paired subdermal needle electrodes (25 and 38-mm long, insulated to within 5 mm of tip) percutaneously inserted to TC , Porcine model. (4 pigs, 8 RLNs at risk), 1 case of Transoral robotic thyroidectomy , A proof of concept for percutaneous technique in remote endoscopic or robotic thyroidectomy without neck incision wound..

Techniques:

Anterior laryngeal (AL) recording electrode placement for intraoperative neural monitoring. (A) Transcartilage Anterior Laryngeal Recording: Skin flaps are elevated superiorly to expose the thyroid cartilage. Needle electrodes are placed onto the subperichondrium layer of thyroid lamina. Inserting the needle at the anterior margin of the thyrohyoid muscle with a 10- to 15-degree angle from the surface of lamina. (B) Percutaneous Anterior Laryngeal Recording: The needle electrodes are percutaneously inserted and fixed onto the perichondrium layer of thyroid cartilage. It may be applied in surgeries with lower/smaller incision wound or in remote surgery. However, excessive traction may cause percutaneous needle displacement during the surgery.

Journal: Frontiers in Endocrinology

Article Title: New Developments in Anterior Laryngeal Recording Technique During Neuromonitored Thyroid and Parathyroid Surgery

doi: 10.3389/fendo.2021.763170

Figure Lengend Snippet: Anterior laryngeal (AL) recording electrode placement for intraoperative neural monitoring. (A) Transcartilage Anterior Laryngeal Recording: Skin flaps are elevated superiorly to expose the thyroid cartilage. Needle electrodes are placed onto the subperichondrium layer of thyroid lamina. Inserting the needle at the anterior margin of the thyrohyoid muscle with a 10- to 15-degree angle from the surface of lamina. (B) Percutaneous Anterior Laryngeal Recording: The needle electrodes are percutaneously inserted and fixed onto the perichondrium layer of thyroid cartilage. It may be applied in surgeries with lower/smaller incision wound or in remote surgery. However, excessive traction may cause percutaneous needle displacement during the surgery.

Article Snippet: Percutaneous , Experimental Clinical , Huang et al., 2020 ( ) , Two disposable paired subdermal needle electrodes (25 and 38-mm long, insulated to within 5 mm of tip) percutaneously inserted to TC , Porcine model. (4 pigs, 8 RLNs at risk), 1 case of Transoral robotic thyroidectomy , A proof of concept for percutaneous technique in remote endoscopic or robotic thyroidectomy without neck incision wound..

Techniques:

Transcutaneous Anterior Laryngeal Recording electrode placement for Intraoperative neural monitoring. (A) Preoperative skin marking: lateral border of thyroid cartilage and the level of true vocal fold. Precise localization may be done with the application of ultrasound (US). (B) The axial view of true vocal folds (white arrow). Lateral side of the thyroid cartilage (TC) lamina is the optimal location to place the skin surface electrodes (US illustration). (C) Transcutaneous recording electrodes are placed at the level of true vocal fold (dotted line). Transcutaneous recording method is applicable in small incision wound or remote thyroid surgery. Skin flap beneath the surface electrodes should be avoided.

Journal: Frontiers in Endocrinology

Article Title: New Developments in Anterior Laryngeal Recording Technique During Neuromonitored Thyroid and Parathyroid Surgery

doi: 10.3389/fendo.2021.763170

Figure Lengend Snippet: Transcutaneous Anterior Laryngeal Recording electrode placement for Intraoperative neural monitoring. (A) Preoperative skin marking: lateral border of thyroid cartilage and the level of true vocal fold. Precise localization may be done with the application of ultrasound (US). (B) The axial view of true vocal folds (white arrow). Lateral side of the thyroid cartilage (TC) lamina is the optimal location to place the skin surface electrodes (US illustration). (C) Transcutaneous recording electrodes are placed at the level of true vocal fold (dotted line). Transcutaneous recording method is applicable in small incision wound or remote thyroid surgery. Skin flap beneath the surface electrodes should be avoided.

Article Snippet: Percutaneous , Experimental Clinical , Huang et al., 2020 ( ) , Two disposable paired subdermal needle electrodes (25 and 38-mm long, insulated to within 5 mm of tip) percutaneously inserted to TC , Porcine model. (4 pigs, 8 RLNs at risk), 1 case of Transoral robotic thyroidectomy , A proof of concept for percutaneous technique in remote endoscopic or robotic thyroidectomy without neck incision wound..

Techniques: